Lytecaster® Recessed Downlighting 1004F13ESR
®
Page 1 of 1
5" Aperture 0 1 Lt 13W Quad / Triple Tube Compact Fluorescent IC Remodeler
3
2
4
5
7 1/2"
OVERALL
HEIGHT
5"
5 1/4"
DIAMETER
3 7/8"
1
5 1/2"
APERATURE
11 3/8"
OVERALL
LENGTH
Ceiling Opening 5 3/8" diameter
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Enclosed
Wall
Washer
Voltage
Lamp
Diffusers
AnodizedReflector AnodizedCone
Satin Cone
Baffles
Basic White
1004F13ESR
120V
13W
1045
1012
1008
1005
1071
1021
1035
Quad or 1046
1012NM
1013
1008NM
1010
1010NM
1005BNM
1005NM
1005WH
1076
1024
1078
1177LX**
1178LX**
1035WH
1085
1095
1096
1096CD
Triple
Tube
1046CD
1013BK
1013BKNM
1013CD
1013CDNM
1013NM
1013WH
1076WH
** Use Triple Tube Lamp Only.
Features
Options & Accessories
AirSeal® Kit: LAS56R
(Required for Airseal Installation)
1. Housing: .032” (#20 ga.) UL listed for direct contact with thermal insulation.
Allows installation in ceilings up to 2" thick. Can be removed for access
to junction box, ballast and ceiling plenum. AirSeal® housing minimizes
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with
Model Energy Code (Section 602.3.3) and Washington State Energy Code
(Section 502.4) and reduces heat loss and condensation in ceiling.
2. Junction Box: 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel.
UL listed for branch circuit wiring supplying connected luminaires. Integral
cable clamps permit attachment of non-metallic (#12 or #14 ga.) Romex®
cable without tools or additional connectors.
Labels
UL (Type IC Suitable for Damp Locations)
Complies with Air Leakage Requirements stated in the Model Energy Code,
California Title 24 and the Washington State Energy Code.
3. Socket Housing: Trim retaining spring secures trim to any height on
housing wall.
4. Socket: (4 Pin, GX24q-1) base, molded thermo-plastic. Pre-wired with
#18 AWG leads to junction box.
Romex® is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.
5. Ballast: Electronic 120V, end of life protected, FCC class “B” consumer
limits, class “A” sound rating. Energy Star® qualified.
Job Information
Type:
Job Name:
Cat. No.:
Electrical
Input Watts: 16
Amps: .13
Ballast Factor: 1.0
Power Factor: .96
Max THD %:10%
Min Start Temp: 0˚F/ -18˚C
Lamp(s):
Notes:
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • B0906
|